blog Che cos'è l'analisi xrf e come realizzare pellet xrf pressati
Che cos'è l'analisi xrf e come realizzare pellet xrf pressati

Che cos'è l'analisi xrf e come realizzare pellet xrf pressati

1 anno fa

What is XRF?

The xrf(X-ray Fluorescence Spectrometry) technique can be used to determine the elemental composition of a sample with a high degree of accuracy. XRF spectrometers work by irradiating a sample with x-rays, which causes the atoms in the sample to emit secondary x-rays of characteristic energies that can be detected and analyzed. This information can then be used to identify the elements present in the sample and to quantify their concentrations.

The capabilities of XRF instrumentation have advanced significantly in the past decade in both sensitivity and stability. As a result, they are no longer the most important source of error in an analysis. This is due to the fact that the overall accuracy of an XRF measurement is now limited by other factors, such as the number of standards used, the homogeneity of the sample, and the stability of the XRF instrument.

Xrf sample preparation is the process of taking a material or substances and preparing it for analysis. This usually involves pulverizing the material, and then creating a homogeneous mixture. The goal of sample preparation is to reduce bias and error, and to produce results that accurately reflect the composition of the material being analyzed. There are many different techniques and practices that can be used for sample preparation, and the choice of which to use depends on the material being analyzed and the desired level of accuracy. In general, though, the goal is to produce a representative sample that is as free of contaminants as possible.

It is however, not without its drawbacks with the main one being the potential for sample contaminationOne of the most common methods of preparing samples for XRF analysis is by making pressed pellets. This process is particularly popular as it produces high quality results, is relatively quick and is a low cost approach. It is however, not without its drawbacks with the main one being the potential for sample contamination. In addition, the pellet must be carefully made to ensure that it is of the correct density and thickness as this can affect the XRF results.

Sample Preparation for xrf

The process of making pressed pellets for XRF analysis begins with grinding the sample to a fine particle size. The sample is then mixed with a binder or grinding aid in a grinding or mixing vessel. The mixture is then poured into a pressing die and pressed at a pressure of between 15 and 35T. The pressed pellet is then removed from the die and dried at a temperature of between 100 and 200 ℃.

A pellet or tablet made by an XRF pellet press is ready for analysis. The XRF pellet press makes a pellet or tablet that is uniform in density and shape. This provides a consistent sample that is easy to handle and measure.

A good starting point is to review the specific elements that will be analyzed and determine the optimal ways to prepare samples for those specific elements. For example, some elements may be better analyzed in an oxidized state while others may be better in a reduced state. Once the specific elements have been considered, the next step is to choose the appropriate method or methods of sample preparation. Common methods include mechanical grinding, chemical digestion, and fusion. Each of these methods has advantages and disadvantages that should be considered before choosing the best approach for a given application. Finally, it is important to optimize the sample preparation protocol for the specific XRF instrument that will be used for analysis. Different XRF instruments often have different requirements for sample preparation, so it is important to consult the instrument manual or a knowledgeable technician before starting sample preparation.

Smaller particles tend to give more accurate results in XRF analysis, so if a sample is particularly coarse it may need to be ground down before analysis. The choice of binder is also important, as some binders can give false readings. Dilution can also be an issue, as too much dilution can lead to inaccurate results. Applying too much pressure to the sample can also lead to inaccurate results, as can making the pellet too thick.

Sample contamination is another factor to consider in XRF sample preparation. Even trace amounts of contaminants can significantly affect the XRF analysis. Care must be taken to prevent sample contamination during preparation, storage, and analysis.

xrf pellet press machine

The Kindle Tech xrf pellet press is a great option for those looking for a fast and easy way to prepare pellets of solid samples for X-ray fluorescence analysis or infrared spectroscopy. This pellet press is able to produce both solid and highly permeable pellets, which makes it a versatile option for a variety of applications. Additionally, the pellet press is designed to be easy to use, so that you can get the most out of your samples.

The automatic xrf pellet press is a kind of equipment specially designed for X-ray fluorescence spectrometer developed by our company on the basis of the automatic tablet press.

The set of fluorescent molds is built-in, and the pressure program of the mold can be automatically converted. The set of molds is also equipped with a safety switch to prevent overloading of the mold during operation.

The XRF pellet press has many advantages that make it an ideal choice for those who want an easy-to-use, reliable machine. For starters, the pressurization and pressure holding are both automated, so you don't have to worry about manually regulating the pressure. Additionally, the machine will automatically relieve pressure when the timer goes off, and it will also eject the pellets when they're finished.

How to prepare xrf sample

Particle Size of xrf sample

One of the key aspects of preparing pressed pellets is to make sure that the sample is ground to a particle size of <75µm, but <50µm is ideal. Particle size is an important factor in determining the success of pressing and pellet quality.

Pulverizing mills are typically used to grind materials into very fine powders. Depending on the sample type and volume, pulverizing mills can usually accomplish this task in a few minutes. Ring and puck pulverizing mills are commonly used for this purpose.

Smaller particle size allows for better compression and more consistent pellets.Small particle size is an important factor in producing pellets that provide the best analytical results because it effects how the sample will compress and bind together when pressed. Smaller particle size allows for better compression and more consistent pellets. This results in less variability and produces a pellet that is more representative of the original sample.

More importantly, samples with larger or variable particle sizes can lead to heterogeneities in the sample. The sampling depth or critical escape depth for elements contained in a sample is energy dependent and, therefore, different for every element. Longer wavelength elements such as Na will have smaller escape depths than shorter wavelength elements such as Fe.

This means that Na analysis is only sampling the first 10µm or so of a sample and thus more susceptible to sample heterogeneities on that scale.

This can be observed as a broad particle size distribution with more particles present at the larger sizes. The increased size variation and larger particle sizes can lead to poor performance of the material and difficulties in processing.

The larger particle sizes at the XRF analysis surface of the sample can lead to analysis errors through the "shadow effect." The shadow effect is when the larger grains shadow the X-ray signal coming from the smaller grains at the surface of the pellet. This can cause the X-ray signal to be weaker, and the analysis to be inaccurate.

Sample binder

The sample binder is a key ingredient in any sample. It literally holds the sample together, providing structure and support. Without a sample binder, the sample would fall apart. The binder also helps to protect the sample from damage and keep it from drying out.

Cellulose and wax are binders that are commonly used in order to keep samples together during grinding. The optimal mixture of these two substances is usually a cellulose/wax mixture that will homogenize with the sample during grinding. This mixture will recrystallize under pressure and bind the sample together.

The sample binders are available under various commercial names but are generally similar.

Sometimes acrylic binders are used, but these are difficult to homogenize with a sample in a mill and need to be mixed by hand. The binding properties of the acrylic binder allow for a stronger bond between the fibers and the matrix, resulting in a composite with increased strength and stiffness. However, the increased stiffness can result in brittleness and a decrease in impact resistance.

Some binder grinding agents are available as pre-mixed pellets that can be automatically added to a mill during grinding.

Sample dilution

The amount of binder added to a sample is an important consideration because it dilutes the sample and must also be added in the same proportion to every sample in order to avoid dilution errors. It's important to be precise when adding binders to a sample in order to maintain consistency and avoid errors.

Since most modern XRF press machines provide substantial intensity for major elements, it is safe to use a significant amount of binder in order to insure a good strong pellet. Binders allow for a more consistent and reliable sample, which is essential for accurate analysis. Pellets made with binders are also less likely to crack or break during the pressing process.

Weak XRF pellets can break in the spectrometer and cause damage to the instrument. This is because the spectrometer is a very sensitive machine and can be easily damaged by weak pellets.

A 20-30% binder to sample ratio will almost always produce a very strong pellet that can be dropped onto the ground from a half a meter without breaking.

If consumable costs are a concern, a lower binder/sample ratio can be used with some experimentation in order to determine the optimal dilution level. This will result in fewer binders being used and therefore fewer consumables being required. In addition, the lower ratio may also improve the performance of the binder, resulting in fewer issues and improved quality.

Suitable pressure

Once a sample and binder are mixed, the material is pressed in a die using a xrf sample press.

The pressure applied to a sample should be sufficient to compress the sample completely and recrystallize the binder.

This can be achieved by using a press with the appropriate die and by applying the recommended pressure for the material being tested One of the most important factors in making sure that the sample is fully compressed so that no void spaces remain in the pellet is to use a press with the appropriate die and by applying the recommended pressure for the material being tested.

A pellet that looks good may still contain void spaces, which can result in a lowered intensity for lighter elements. As a result, it is important to measure the pellets before using them to ensure that they will provide the desired level of intensity.

If you're looking to get the most out of your light element samples, you should experiment with increasing pressure until the intensity for the light elements reaches a maximum and stabilizes. By doing this, you'll be able to get a clear and accurate reading for your light element analysis.

When a sample is placed in a pressure vessel and pressurized, the sample will undergo deformation. The amount of deformation that occurs is a function of the material's yield strength and the pressure applied. Most samples will reach their maximum deformation at 25-35T of pressure applied for 1-2 minutes.

It's important to release the pressure applied to a sample slowly to prevent cracking of the sample surface. Cracks can occur when the pressure is released too quickly, causing the sample to break apart.

xrf sample thickness

The pellet must be infinitely thick to the X-ray beam for all of the elements that are being measured. X-rays produced in the sample must be able to escape the sample without being reabsorbed in order to make it to the detector to be measured. Higher energy elements (usually those with higher atomic numbers) will have deeper escape depths in a sample relative to lower energy elements. The signal coming from higher energy elements sample more of the pellet than those coming from lower energy elements. The sample's ability to reabsorb X-rays is directly proportional to the sample's average atomic mass.

The absorption capability of any sample can be calculated from its average elemental composition and the mass absorption coefficient for each element present. The mass absorption coefficient (MAC) is a measure of how well a substance absorbs electromagnetic radiation. The higher the MAC, the more the substance absorbs.

The problem arises when the escape depth of a particular element is larger than the thickness of the pellet.

For example, Pellet "A" may press well for element "B" but not for element "C". The main thing to remember is to test each new pellet on the element type it is intended to be used on before actually using it in production.Pellets are small, round pieces of material that are used in a variety of applications. In the context of element pressing, pellets are often used to press elements into place. Because each element type is different, it is important to test each new pellet on the element type it is intended to be used on before actually using it in production. This way, you can be sure that the pellet will provide the desired results.

Because this is an element dependent issue, a particular pressed pellet may provide good results for some elements but not others.

You should make sure your pressed pellet is thicker than the escape depth of the highest energy element. This will help ensure that all of the high energy particles are trapped in the pellet and can be measured accurately.

Usually a pellet made with 8-10g of sample for a 32mm diameter pellet or 13-15g of sample for 40mm diameter pellet will be sufficiently thick for the elements.

Sample contamination

If the sample is not homogeneous, for example when it contains inclusions, the resulting pellet may not be representative of the entire sample. In such cases, the inclusion may contribute a significant signal that is unrelated to the matrix. If the pellet is not pressed evenly, the resulting signal from the pellet surface may not be representative of the entire pellet.To avoid sample contamination and ensure that the pellet is representative of the entire sample, it is important to use a high quality pellet press and to evenly distribute the sample throughout the pellet. Additionally, it is important to clean the pellet press between samples to avoid cross contamination.

Contamination usually occurs during the sample grinding process and originates from two main sources: the sample preparation device and sample to sample cross contamination. The most common type of contamination is wear debris from the sample preparation device, which can be introduced into the sample during grinding. In some cases, this contamination can be removed by taking precautions to prevent cross contamination between samples.

Contamination from the Sample Preparation Device

Sample pulverizers are the sample preparation devices that have the potential to contribute the most contamination to a sample. high-speed devices, they can break down a sample very quickly, but they can also create a lot of dust and aerosumables that can contaminate a sample. If not used properly, sample pulverizers can introduce a significant amount of error into a analysis.

A pulverizer is a machine that grinds samples from a coarse state to a fine powder. The most common type of pulverizer is the ring and puck style grinding bowl, which is used to grind samples from a few millimeters in diameter to a fine powder.

The material that you choose to grind your sample with can introduce foreign elements to your final product. In order to avoid this, care must be taken when choosing the grinding medium.

Steel, tungsten carbide and ceramics such as alumina and zirconia are the most common choices.

Steel can add Fe, Ni and Cr, tungsten carbide will add W and alumina and zirconia will add Al and Zr respectively. It is, therefore, important to consider what elements are being analyzed and choose the grinding vessel accordingly to avoid contamination.

Tungsten carbide is a common choice for many applications because it is one of the hardest metals. It is also less likely to be a key element for analysis in many applications. However, tungsten carbide is often the most expensive option.

Sample to Sample Cross Contamination

Cross contamination during sample preparation is a major issue when it comes to analysing samples for contaminants. It can potentially introduce bias and skew results, making it difficult to draw accurate conclusions. To minimise this risk, rigorous cleaning protocols must be put in place and adhered to at all times.

It is important to avoid potential sources of cross contamination at all costs.One way to avoid cross contamination is to have a dedicated area for each type of sample. This way, there is no risk of one type of sample coming into contact with another. Another way to avoid cross contamination is to use separate instruments for each type of sample. This ensures that there is no risk of one type of sample coming into contact with another. Finally, it is important to use appropriate personal protective equipment (PPE) when working with samples. This includes gloves, aprons, and face masks. By using PPE, you can minimize the risk of cross contamination.

Preparation of Calibration Standards and Routine Samples

As with all analytical techniques, the accuracy and precision of XRF results are a function of many factors, including the calibration of the instrument, the operator's expertise, the sample preparation, and the choice of analytical method. However, XRF is generally considered to be a very accurate and precise technique.

Calibration standards and unknown samples must be prepared in the same manner to ensure accurate analysis. This is because different preparation methods can lead to different results. Thus, if calibration standards and unknown samples are prepared in different ways, the accuracy of the analysis will be compromised.

Summary

There are several common factors that contribute to error in the preparation of pressed pellets. The particle size of the sample can affect the accuracy of the pellet, as well as the choice of binder. The dilution ratio and the amount of pressure applied to the sample can also influence the final pellet. The thickness of the pellet and the sample to sample cross contamination are also common contributors to error.

When crafting methods to limit error, it is important to be mindful of detail and consistent in vigilance. This means having a clear and well-documented method, as well as being consistent in following the protocol. Good method development requires an understanding of the subject matter and a dedication to accuracy. Once a method is developed, it is important to limit sources of variability by adhering to best practices for data collection, analysis, and interpretation.

CONTATTATECI PER UNA CONSULENZA GRATUITA

I prodotti e i servizi di KINTEK LAB SOLUTION sono stati riconosciuti da clienti di tutto il mondo. Il nostro personale sarà lieto di assistervi per qualsiasi richiesta. Contattateci per una consulenza gratuita e parlate con uno specialista del prodotto per trovare la soluzione più adatta alle vostre esigenze applicative!

Prodotti correlati

Laboratorio automatico XRF & KBR Pellet Press 30T / 40T / 60T

Laboratorio automatico XRF & KBR Pellet Press 30T / 40T / 60T

Preparazione rapida e semplice dei pellet di campioni xrf con la pressa automatica per pellet da laboratorio KinTek. Risultati versatili e accurati per l'analisi di fluorescenza a raggi X.

XRF e anello d'acciaio KBR laboratorio polvere Pellet stampo di pressatura

XRF e anello d'acciaio KBR laboratorio polvere Pellet stampo di pressatura

Producete campioni XRF perfetti con il nostro stampo per la pressatura di pellet di polvere da laboratorio ad anello in acciaio. Velocità di pressatura e dimensioni personalizzabili per uno stampo sempre preciso.

XRF & KBR anello di plastica laboratorio Polvere Pellet stampo di pressatura

XRF & KBR anello di plastica laboratorio Polvere Pellet stampo di pressatura

Ottenete campioni XRF precisi con il nostro stampo per la pressatura di pellet di polvere da laboratorio ad anello in plastica. Velocità di pressatura e dimensioni personalizzabili per uno stampo sempre perfetto.

XRF Acido borico laboratorio polvere Pellet stampo di pressatura

XRF Acido borico laboratorio polvere Pellet stampo di pressatura

Ottenete risultati accurati con il nostro stampo per la pressatura della polvere di acido borico XRF da laboratorio. Perfetto per preparare i campioni per la spettrometria di fluorescenza a raggi X. Dimensioni personalizzate disponibili.

Pressa per pellet idraulica elettrica per XRF & KBR 20T / 30T / 40T / 60T

Pressa per pellet idraulica elettrica per XRF & KBR 20T / 30T / 40T / 60T

Preparate i campioni in modo efficiente con la pressa idraulica elettrica. Compatta e portatile, è perfetta per i laboratori e può lavorare in un ambiente sotto vuoto.

Supporto per campioni XRD / vetrino per polveri del diffrattometro a raggi X

Supporto per campioni XRD / vetrino per polveri del diffrattometro a raggi X

La diffrazione di polvere a raggi X (XRD) è una tecnica rapida per identificare i materiali cristallini e determinare le dimensioni delle loro celle unitarie.

Macchina automatica della pressa della pallina del laboratorio 20T/30T/40T/60T/100T

Macchina automatica della pressa della pallina del laboratorio 20T/30T/40T/60T/100T

Provate la preparazione efficiente dei campioni con la nostra pressa automatica da laboratorio. Ideale per la ricerca sui materiali, la farmacia, la ceramica e altro ancora. Presenta dimensioni compatte e funzionalità di pressatura idraulica con piastre riscaldanti. Disponibile in varie dimensioni.

pressa per pellet kbr 2T

pressa per pellet kbr 2T

Vi presentiamo la KINTEK KBR Press, una pressa idraulica da laboratorio portatile progettata per gli utenti di livello base.

Pressa manuale della pallina del laboratorio per la scatola di vuoto

Pressa manuale della pallina del laboratorio per la scatola di vuoto

La pressa da laboratorio per vacuum box è un'apparecchiatura specializzata progettata per l'uso in laboratorio. Il suo scopo principale è quello di pressare pillole e polveri in base a requisiti specifici.

Pressa per pellet isostatica a freddo manuale (CIP) 12T / 20T / 40T / 60T

Pressa per pellet isostatica a freddo manuale (CIP) 12T / 20T / 40T / 60T

La pressa isostatica manuale da laboratorio è un'apparecchiatura ad alta efficienza per la preparazione dei campioni, ampiamente utilizzata nella ricerca sui materiali, in farmacia, nelle industrie ceramiche ed elettroniche. Consente un controllo preciso del processo di pressatura e può lavorare in un ambiente sotto vuoto.

Obiettivo sputtering di ferro (Fe) di elevata purezza / polvere / filo / blocco / granulo

Obiettivo sputtering di ferro (Fe) di elevata purezza / polvere / filo / blocco / granulo

Cercate materiali di ferro (Fe) a prezzi accessibili per uso di laboratorio? La nostra gamma di prodotti comprende bersagli per sputtering, materiali di rivestimento, polveri e altro ancora in varie specifiche e dimensioni, su misura per soddisfare le vostre esigenze specifiche. Contattateci oggi stesso!

Fluoruro di stronzio (SrF2) Target sputtering / Polvere / Filo / Blocco / Granulo

Fluoruro di stronzio (SrF2) Target sputtering / Polvere / Filo / Blocco / Granulo

Cercate materiali al fluoruro di stronzio (SrF2) per il vostro laboratorio? Non cercate oltre! Offriamo una vasta gamma di dimensioni e purezza, compresi bersagli per sputtering, rivestimenti e altro ancora. Ordinate ora a prezzi ragionevoli.

Obiettivo di sputtering di elevata purezza in ossido di afnio (HfO2) / polvere / filo / blocco / granulo

Obiettivo di sputtering di elevata purezza in ossido di afnio (HfO2) / polvere / filo / blocco / granulo

Ottenete materiali di ossido di afnio (HfO2) di alta qualità per le vostre esigenze di laboratorio a prezzi accessibili. I nostri prodotti personalizzati sono disponibili in varie dimensioni e forme, tra cui bersagli sputtering, rivestimenti, polveri e altro ancora.


Lascia il tuo messaggio